Release Notes (SkinScanner-U)

Descriptive Highlights

For further details, please see the Technical Highlights below.

v6.5 - R2407, Release date: 01-08-2024, Notes:

  • Ultrasound center line marking on both modalities for tracking

    • While scanning, the center of the ultrasound image is marked with a dashed line in the middle. On the optical image, the center is also marked in the middle of the red guideline.

R2407 Skinscanner center line.png

 

  • Number of maximum recordable frames extended

    • The maximum length of recorded cineloops can now be set to 300. Users can still choose to keep the maximum record length to 100 frames.

R2407 Skinscanner 300 frames.png

 

v6.4 - R2405, Release date: 21-06-2024, Notes:

  • Redesigned upload wizard

    • The upload screens were redesigned to give users more control. The saving options remain on the screen while the user navigates through the catalog hierarchy.

  • Users can now download or upload the current frame on display even when it’s not selected

    • This allows for faster work when browsing records.

 

v6.3 - R2403, Release date: 10-04-2024, Notes:

  • New feature: volume estimation for lesions (in Capture)

 

v6.2 - R2401, Release date: 15-02-2024, Notes:

  • Redesigned download screen with new features

The download interface has been simplified for a more streamlined user experience. Users can now download multi-frame record loops as MP4 videos that can be viewed outside the web app. Additionally, users can now attach patient metadata – such as patient name and/or insurance number – to downloaded images and PDF reports. Dermus continues its practice not to store any personally identifiable information in the SkinAid Catalog database to ensure patient anonymity. Note that PDF reports may be emailed too instead of a direct download.

  • Value annotation

Users now have the option to annotate both optical and ultrasound images by reading out the RGB or intensity values around the selected location.

  • Product switch option on Login page

Users now have the option to switch to SkinAid Catalog directly on the login page for easier accessibility.

 

v6.1 - R2311, Release date: 18-12-2023, Notes:

  • HighResolution vs HighDepth Options during scanning

Users have the ability now to choose between high-resolution and high-depth data recording. The latter allows better visualization of deeper skin structures in sacrifice of the higher resolution of the epidermis and dermis.

  • Option to highlight a selected modality (optical or ultrasound) by enlarging its window over the other modality

SkinScanner data recording is simultaneously generating both optical and ultrasound images. This feature enables users now to focus only on one of the modalities during data recording, whilst moving the other image screen to the background.

  • FW update for each users is possible

Firmware update has been made simple by a single-click interaction.

  • Feedback button: Report an Issue - Send Feedback

Users are encouraged to provide instant feedback in case of any unlikely malfunctions experienced or bugs noted; or in contrary, to give a compliment or express a new functionality need. This feature sends some basic information (e.g. firmware number, device UID) about one’s device to Dermus as well as it provides space for textual description of the feedback and the ability to attach a screenshot automatically prepared for the user by the system.

v6.0 - R2310, Release date: 20-11-2023, Notes:

  • Separate domain for SkinScanner Capture (dermus.app) and SkinAid Catalog (skinaid.app) products

Considering product evolution (two separable data services) and regulatory matters (medical vs. non-medical) SkinScanner Capture and SkinAid Catalog have been moved to two distinct domains.

  • Updated Login screen and Hint to install app icon on home screen

A revised login screen has been introduced for simplicity. Installing and starting from an app icon on the MCU home screen may result in a better user experience while using SkinScanner Capture.

  • New navigation sidebar

The new navigation sidebar allows a single-click switch between SkinScanner Capture and SkinAid Catalog (see the icons on the bottom of the screen).

v5.9.0 - R2309, Release date: 09-10-2023, Notes:

  • Shutter time as optical gain (instead of SW gain)

From now on it is possible to adjust different shutter times during live recording (as optical gain) and edit the brightness of the captured images in the SkinAid Capture screen. This improvement may be complemented with the already existing software-based image brightness adjustment available post-recording.

Technical Highlights

(Release Notes of the SkinScanner Capture web-app:)

v6.5 - R2407, Release date: 01-08-2024, Notes:

  • Ultrasound center line marking on both modalities for tracking

  • Number of maximum recordable frames extended

  • Patient data and metadata inclusion in downloaded images can be turned off

  • Calibration fixes

v6.4 - R2405, Release date: 21-06-2024, Notes:

  • Redesigned upload wizard

  • Full screen display remains in full screen mode when switching products

  • Enhanced and more detailed calibration process

  • Downloaded files now have more detailed filenames

  • Improved file compression and quality for downloading multi-frame loops as a video

  • Users can now download or upload the current frame on display even when it’s not selected

  • SkinScanner schematic image updated according to the latest hardware design

  • Numerous quality and stability improvements

v6.3 - R2403, Release date: 10-04-2024, Notes:

  • New feature: volume estimation for lesions (in Capture)

  • Detection of an unsupported OS, host device, or browser

  • Ability to return to an existing scan after any activity in the side menu

v6.2 - R2401, Release date: 15-02-2024, Notes:

  • The whole download dialog screen is upgraded and extended

  • Export/download images and pdf reports with additional meta-data: patient name and insurance nr. (while not storing any identifiable data by Dermus)

  • Export/download multi-frame 'cineloop' recording as MP4 video

  • Option for annotating optical and US images by reading out the RGB or Intensity values around the picked location

  • Ability to switch products directly on the Login screen

v6.1 - R2311, Release date: 15-12-2023, Notes:

  • There is no need for Login once switching between Products

  • HighResolution vs HighDepth Options during scanning

  • Option to highlight a selected modality (optical or ultrasound) by enlarging its window over the other modality

  • Option in Preferences for OPT image sharpening

  • For all new users, by default, a shifted US soft-gain is set

  • FW update for each users is possible

  • Change the URL and app icon to the reddish version of the old SkinScanner logo

  • Feedback button: Report an Issue - Send Feedback

  • Interactive image display during cineloop cropping in Capture

v6.0 - R2310, Release date: 20-11-2023, Notes:

  • Separate domain for SkinScanner Capture (dermus.app) and SkinAid Catalog (skinaid.app) products

  • Updated Login screen

  • New navigation sidebar

  • Hint to install app icon on home screen

  • Performance enhancements: frame sync, packet numbering, and GPU optimization

v5.9.0 - R2309, Release date: 09-10-2023, Notes:

  • Shutter time as optical gain (instead of SW gain)

  • No calibration message on Capture and Records screens (in case of uncalibrated devices)

  • Ruler colouring option in preferences

  • Fixed red triangle behaviour on the optical image

v5.8.0 - R2308, Release date: 12-09-2023, Notes:

  • Calibration Report export to PDF

  • Explicit edit status for filters

  • Save device serial nr. and FW info to Records (not shown on UI)

v5.7.0 - R2307, Release date: 07-08-2023, Notes:

  • Developer mode for Capture screen

  • Bug fixes and improved stability

  • Calibration framework updated

  • AIO firmware update

v5.6.0 - R2306, Release date: 04-07-2023, Notes:

  • Support for max. 12mm US depth

  • Optical gain discretized

  • Compatibility with the latest Firmware

v5.5.0 - R2305, Release date: 02-06-2023, Notes:

  • Demo mode on skinaid.app/capturedemo

  • New annotation marker

  • Free text note option on capture screen

  • Icons changed and redesigned in Capture screen

  • Custom slider for tuning shows difference from default values

  • Rulers and number of images are upgraded in Capture screen

  • Pan & zoom added for optical images also

  • New release notification added to each user at first login in Patient and Capture screen

  • USB related messages redesigned

v5.4.0 - R2304, Release date: 9-05-2023, Notes:

  • Pan/Zoom/Gain are saved as metadata info

  • Pan/Zoom loaded on record screen

  • Store US data in 16bit

  • Capture enhancement

  • New login and registration UI

  • Add user preferences screen

v5.3.0 - R2303, Release date: 31-03-2023, Notes:

  • FW version display fix

  • New capture UI design + annotation on Capture screen

  • More GPU support

  • Measurement and annotation handle in db

  • Ability to receive envelopes

  • Login page fix

  • New navigation bar

v5.2.0 - R2302, Release date: 30-02-2032, Notes:

  • Bugfix: SCANU-1206, EEPROM data read properly after calibration

  • Show cineloop icon next to cineloop recording

  • Show us image with grayscale colormap when segmentation overlay is switched on

  • New slider UI

v5.1.1 - R2301, Release date: 30-01-2032, Notes:

  • Display all three measurement distances on the Capture screen

v5.1.0 - R2212, Release date: 20-12-2022, Notes:

  • Support page added

  • Cine-loop section selecting and saving functionality added

  • Option added after successful saving: Go to capture page or review recently saved records

v5.0.0 - R2211, Release date: 28-11-2022, Notes:

  • Optical image stability improved

  • User is now notified about offline/online changes in internet connection

  • Saving process (from capture page) upgraded: cancelling option, progress bar added

  • OK button added for error modal

  • Linking Capture screen to single lesion pages further improved

  • Registration process upgraded

  • Bugfix in Firmware versions display (/usb-settings)

  • Bugfix: 'US image brightness is different on Capture vs Record review screen'

v4.5.0 - R2210, Release date: 28-11-2022, Notes:

  • Thickness measurement upgraded

  • Option to full screen mode on capture screen added

  • Saved frames/cineloop are now indicated by the corresponding icons changing color to red

  • Device information added to record

  • Capture page linked to single Lesion pages: captures can now be initialized from single lesion pages of SkinAid

  • Firmware versions are now displayed in the web-app (/usb-settings)

v4.4.0 - R2209, Release date: 14-09-2022, Notes:

  • Capture screen updated on mobile host devices

  • Handling inputs from device save button added

v4.3.0 - R2208, Release date: 02-09-2022, Notes:

  • Bugfix: 'Optical stream starts before integration time is sent to host' - SKINAID-427

  • Bugfix: 'Unnecessary paranthesis on Close Exam window' - SKINAID-418

  • Bugfix: 'Frame numbers start at zero when saving image pair and cineloop' - SKINAID-422

  • Progress bar for device communication initialization added - SKINAID-417

v4.2.0 - R2207, Release date: 26-07-2022, Notes:

  • Bulk EERPOM read implemented

  • USB Failure WatchDog and reset option added on '/usb-settings' page

  • FPGA FW update option added on '/usb-settings' page

  • STM32 FW update added on '/usb-settings' page

  • 'Optical image size update' bug fixed

  • US A-line length set to 1250 and now shows a 9 mm region only

v4.1.0 - R2206, Release date: 04-07-2022, Notes:

  • Calibration page added

  • Parameters are now loaded from the EEPROM of the imaging device (Dermus SkinScanner) on the capture page

V3.2.0, Release date: 24-08-2021, Notes:

  • US lesion measurements added

V3.1.0, Release date: 10-08-2021, Notes:

  • Segmentation feature added

V3.0.1, Release date: 01-07-2021, Notes:

  • New UI design implemented

  • Opto-fuse modified to demo version

  • PDF report generation improved

V3.0.0, Release date: 25-06-2021, Notes:

  • Opto-fuse functionality added

V2.1.0, Release date: 19-04-2021, Notes:

  • Navigation bar updated

  • ICD diagnosis option added

  • Patient ID input removed; Patient ID is now automatically generated

  • 'About' menu added

  • 'Settings' menu added

  • Predefined tags introduced for 'Notes' fields

V2.0.0, Release date: 01-01-2021, Notes:

  • DICOM compatibility added

  • Annotation added to DICOM file

  • 'Multiple use is logged in' bug fixed

V1.0.0, Release date: 01-09-2020, Notes:

  • First release